Modular solutions from a single data hall to a whole campus, for new builds, retrofits and ongoing expansion.

Request a site assessment
1MW–1GWthree tiers of data centers
1.204annual PUE of the 8 MW reference design (design estimate)
800kVAmax modular UPS capacity
6300Amax busway rated current
Global complianceCampus and data hall projects are designed to the grid, certification and installation codes of the country they're built inLearn more →

Three tiers of data centers

Edge

< 7.5 MW

On-site AI edge nodes

Retrofit existing rooms with structural, power and cooling upgrades; prefabricated contained-aisle pods and compute containers; remotely managed operations.

Metro

7.5–20 MW

Metro AI data centers and operations hubs

Buildings and compute equipment delivered as a system; on-premises AI deployment and operations services.

Regional

100 MW–1 GW

Regional AI hubs

Campuses and buildings planned together with on-site generation, grid connection, load and energy storage; liquid-cooled cluster integration and reliability validation.

Contained-aisle pods and campus systems

A contained-aisle pod combines racks, aisle containment, power distribution, cooling, access control and monitoring in one unit, well suited to retrofitting existing rooms.

SystemProductsRange
Contained-aisle podsContained cold aisle, contained hot aisle, fan wallTwo rows 3,600 mm wide, 2,000 or 2,200 mm high; in-row cooling 25 / 40 / 48 / 60 kW
UPSRack, tower and modular UPS3–40 kVA; 10–160 kVA; 50–800 kVA; efficiency above 96%
BuswayCompact busway, smart busway250–6300 A;100–1250 A
Backup powerDiesel generator sets1,000–2,000 kW prime power per unit, automatic paralleling
Cooling plantLiquid-cooling plant modules, integrated chiller-plant modules100–1,200 kW; 100–1,000 RT, free cooling supported
MonitoringDCIM and digital twinUnified data from power, cooling and environment; alarms, capacity, asset management and PUE analysis

Product Handbook

Get the product handbook

Specifications, selection guidance and delivery scope for the full Rack, Container and Campus range, in one PDF.

Privacy:how we handle the information you submit

Your Site, Simulated

Run your own site in the twin

We'll build a digital twin from these conditions and walk you through it on a video call. Fill in whatever you know.

Site type

Privacy:how we handle the information you submit

Leads

Leads

Contacts from the four forms on the site. Only you and editors can see them, and each submission is also emailed to [email protected].