Global complianceBuilt to local codes across the Americas, Europe, the Middle East, Africa and Asia-PacificLearn more
SINOWISE
Site assessment
Inside a SwiftMDC container data center

SwiftMDC Megawatts of AI compute,
no data center build needed

Racks, power distribution, liquid cooling, monitoring and fire protection are integrated and tested in the factory, shipped to site as complete containers and put into service once power and cooling are connected.

Configure your SwiftMDC →
80kW–20MWacross three configurations
120kWMax density per rack
1024GPUs per POD
8–12weekssingle container
3–5monthsMW-scale delivery
Global complianceComponents from the latest NVIDIA AVL, built to grid and certification rules worldwideLearn more →
Container data center clusters

Megawatt-scale AI infrastructure,
delivered as one system

More than a box: each SwiftMDC integrates compute, networking, liquid cooling, power distribution and monitoring into one deployable system, available as an infrastructure-only edition or fully integrated with servers.

Three configurations

ConfigurationEnclosureTotal powerGPU countCoolingDensity per rackTypical use
AI-Edge Edge inference20 ft ISO container80–200 kW8–16Air-cooled, liquid optionalup to 30 kWEdge inference, smart manufacturing, 5G edge
AI-Core Training and fine-tuning40 ft ISO high-cube300–600 kW32–64Cold-plate liquid cooling, integrated CDUup to 100 kWLLM training, fine-tuning, university research
AI-Flex Hyperscale clusters4 to 20+ interconnected 40 ft modules2–20 MW256–2,048+Central liquid cooling with distributed CDUs, immersion optionalup to 120 kWLarge-scale training, AI cloud services, AI data centers

Designed for megawatt loads

Reference specification for one POD, assuming 8-GPU B300 servers.

GPUs per POD1,024
Servers128
Compute racks at 119.8 kW each16
Network and storage racks08
IT loadabout 2 MW

From one container to a cluster

Single container

80–600 kW

One AI-Edge or AI-Core container

1 POD

about 2 MW

Two compute units, 1,024 GPUs

3 PODs

6.09 MW

8 MW reference design, 3,072 GPUs

AI-Flex cluster

2–20 MW

4 to 20+ interconnected modules

Scope of delivery

You provide the site; SINOWISE delivers the compute infrastructure as one system. Final configuration, site interfaces and the deployment plan are fixed at design review, before anything ships.

You provide

  • Footprint and maintenance space
  • Access for transport and lifting
  • Utility power connection
  • Network connection
  • Local permits and external services

SINOWISE delivers

  • Containers, liquid-cooled racks and modular compute units
  • Power distribution, cooling plant and coolant piping
  • Prefabrication, on-site assembly and system testing
  • Central monitoring and digital twin
  • Maintenance and expansion support

You get

  • Compute ready for service
  • Training, fine-tuning and inference
  • Keep adding PODs

Set per project: workloads and equipment, site, power and climate, reliability targets and operations needs, scope boundaries and phasing.

One container, week by week

Sample schedule, counted from when the site and power are ready.

W0–1Design review and order
W1–7Factory prefabrication
W7–8Factory acceptance test
W8–10Shipping and placement
W10–12Commissioning and go-live

Based on the 8–12 week target for a single container; final schedules are set in the project contract.

Product Handbook

Get the product handbook

Specifications, selection guidance and delivery scope for the full Rack, Container and Campus range, in one PDF.

Privacy:how we handle the information you submit

Your Site, Simulated

Run your own site in the twin

We'll build a digital twin from these conditions and walk you through it on a video call. Fill in whatever you know.

Site type

Privacy:how we handle the information you submit

Leads

Leads

Contacts from the four forms on the site. Only you and editors can see them, and each submission is also emailed to [email protected].