Global complianceBuilt to local codes across the Americas, Europe, the Middle East, Africa and Asia-PacificLearn more
SINOWISE
Site assessment
Cooling plant, CDUs, cold-plate racks and immersion tanks

Liquid-cooled racks
compute and cooling, integrated at the factory

Racks are cabled, fitted with manifolds, leak-tested and burned in at the factory; on site they only need to be placed and connected to power and coolant.

Request a site assessment
2optionsliquid cooling: cold plate and immersion
≥ 2000kgMGX rack rated static load
34–44°Csecondary loop (93–111 °F), dry-cooler ready
1400kWmax room-level CDU capacity
150kWmax heat rejection per immersion tank
Global complianceKey components from the latest NVIDIA AVL; racks built to local codes worldwideLearn more →
Three MGX rack models

AI Rack Hub MGX 1.1 Rack

One rack, three models

Built to the NVIDIA MGX 1.1 rack geometry. Sites without liquid cooling can start with the air-cooled model and later convert the same rack to cold-plate cooling without changing layout, power or cabling.

Cooling pathFull-height manifolds on both sides, connected to the facility water loop
Supported nodesRTX PRO 5500 cold-plate modules, RTX PRO 6000 SE cold-plate nodes, DGX B300 (expansion bay)
Best forMainly inference and RAG, with fine-tuning and training

Cold-plate cooling equipment

The coolant distribution unit (CDU) is the heart of a cold-plate system, with variable-speed pumps and hot-swappable key components.

TypeRated cooling capacitySecondary flowDimensions (W × D × H)Best for
Rack-mount CDU15 / 20 / 30 / 40 kW2.4–4.5 m³/h436 × 850–880 × 175 mmOne or a few racks
In-row CDU120 / 200 / 400 / 600 / 900 kW15–110 m³/h600–1000 × 1200 × 2200 mmInstalled in the row, one per row
Room-level CDU300 / 500 / 1400 kW36–105 m³/h600–900 × 1200 × 2200 mmConnects to the facility loop, with built-in automatic make-up
Manifolds30 × 30 or 40 × 40 mm, 1–30 branches, 304 stainless steel; flow variation under 4%; 100% helium leak-tested
Secondary loop networkDN25–DN150 prefabricated 304 stainless piping; flow variation under 10%; leak location detection

Immersion tanks

Standalone tanks offer more capacity with an external CDU; all-in-one tanks build the heat exchanger and pump into the tank and are plug-and-play.

TypeHeat rejectionCapacityNet weightDimensions (W × D × H)
Standalone26 kW21U350 kg1100 × 800 × 1200 mm
45 kW36U600 kg1800 × 800 × 1200 mm
60 kW48U800 kg2300 × 800 × 1200 mm
75 kW60U1000 kg2900 × 800 × 1200 mm
150 kW60U1100 kg3200 × 800 × 1200 mm
All-in-one7 kW (air)6U305 kg1000 × 800 × 1150 mm
14 kW (air)12U610 kg2000 × 800 × 1150 mm
15 kW (liquid)12U360 kg800 × 800 × 1150 mm
24 kW (liquid)18U500 kg1200 × 800 × 1150 mm
30 kW (liquid)24U720 kg1600 × 800 × 1150 mm

Product Handbook

Get the product handbook

Specifications, selection guidance and delivery scope for the full Rack, Container and Campus range, in one PDF.

Privacy:how we handle the information you submit

Your Site, Simulated

Run your own site in the twin

We'll build a digital twin from these conditions and walk you through it on a video call. Fill in whatever you know.

Site type

Privacy:how we handle the information you submit

Leads

Leads

Contacts from the four forms on the site. Only you and editors can see them, and each submission is also emailed to [email protected].